Page 69 - HOLE_MAKING_CATALOG_INCH_2022_P373-P446
P. 69

USER GUIDE
                                                                                                                         TAPS

             General Recommendations (Regrinding)


                  Maintenance                                                         Picture 6
                  It is important to periodically regrind the worn tap. This
                  is to avoid permanent damage or even tool breakage.
                  The Grinding Wheels
                  The structure and grain of grinding wheels must
                  be appropriate for the tap to be resharpened.
                  Taps for Cast Iron
                  Taps used on cast iron can rarely be resharpened, as
                  it is very abrasive and tends to wear the flank in such
                  a way that it becomes grossly out of tolerance.                                  Chamfer out
                                                                                                   of center
                  Taps for Aluminun
                  After regrinding it is advisable to remove
                  the steel burrs with a wire brush.

                  Tap Inspection
                  It is important to inspect the tap after regrinding
                  to ensure that all of the dimensions and angles
                  have remained according to its specifications.

                  Controls (tests)
                  Once the tap is resharpened, it is always
                  best to test it to correctly obtain the same                        Picture 7
                  threads as when the tap was new.                                   a
                •  The chamfer must be perfectly on axis
                  in order to avoid the effects of picture 6.                           3
                  The cutters must have correct divisions.                                              b
                •  The results of resharpening with an incorrect
                  division is shown in picture 7.
                •  The length and number of threads in chamfer must
                  be precisely identical to those of the new tap.
                                                                        2                            4








                                                                                     1
                                                                                         γ
                                                                            Incorrect division-cutters not concentric

























                                                                                                                      441
   64   65   66   67   68   69   70   71   72   73   74