Page 84 - Turning_catalog_INCH_2022_45_P1-112
P. 84

ISOTURN TOOLS  ISOTURN JHP Tools                          1           Insert Indexing Procedure  USER GUIDE








              The unique High-Pressure coolant system is composed
              of a static housing and telescopic tube to direct the
              coolant exactly to the cutting edge of the insert. The
              telescopic tube embedded in the housing skews right
              and left, according to the working direction of the tool
              (see drawing). The advantage of this system is that
              there is no need to detach the housing of the tool
              when changing an insert. This reduces setup time.







                                                       ap .10   2

                                                ap= .10









              To mount or change an insert, press on the
              telescopic tube in a backward direction.
              After indexing the cutting edge of the insert,
              starting the coolant will extract the tube        3
              automatically to its operating position.




                       4°
                               Central Coolant Direction
                          4°
                            (8° rotation adjustment)




                                                                4



























    82   ISCAR
   79   80   81   82   83   84   85   86   87   88   89