Page 31 - HOLE MAKING CATALOG p311-382
P. 31

USER GUIDE  REAMERS

Setting Methods

       There are two optional setting methods - comparison
       micrometer and setting device. Comparison micrometer
       with dial gauge, although a low cost solution and readily
       available for small workshops, is prone to damaging
       the cutting edge and therefore not recommended.

       Using a Comparison Micrometer
       Set the micrometer to the correct diameter using the
       precision blocks. Adjust the frontal diameter and back
       taper by turning the adjustment screw clockwise.
       The frontal diameter should be larger than the rear
       diameter by approximately 0.015 mm.(0.6 µin).

       Using a Setting Device
       ISCAR’s mechanical setting device enables easy,
       quick and accurate adjustment. Due to its modular
       construction, it can be used for standard, special
       and more complicated reamer adjustments.

       Setting Device Located Between Centers
    •	 Shorter setting time
    •	 Modular system
    •	 Higher accuracy
    •	 No risk of damaging the cutting edge

                                                                              341
   26   27   28   29   30   31   32   33   34   35   36